Lumenfacade Inground Dynamic White
Tunable ground-recessed lighting
The Lumenfacade Inground Dynamic White is a ground-recessed LED luminaire with a special Lumenpulse feature that allows smooth variations in color temperature (from 2200K to 3000K or from 2700K to 6500K). Ideal for indoor hospitality applications or heritage and red brick architecture, Dynamic White gives architects and designers the flexibility to adjust the ambience of spaces and façades, as needed. Featuring second generation LED technology, the Lumenfacade Inground Dynamic White is available in four different sizes (12 in, 24 in, 36 in or 48 in), with a wide choice of outputs, optics and controls. A unique asymmetric wallwash distribution is also available, providing exceptional uniformity and brightness for walls and signage.
Videos
Downloads
Documents (0)
0.00/250 MBCertifications
UL Certificate of Compliance
ZIPdownloadadd
Product Configurator
Your Product Code
LOI 120/277 __ __ __ __ __
Housing 1 2 3
Voltage
Length
Color and Color Temperature
Optic
Optical Option
Control
- 1 A Lumenfacade Inground fixture includes one optical chamber (LOIC), one power and control box (PACBOX) and one recessed blockout (RBO). The LOIC, PACBOX and RBO are provided according to the output/color, length and control configuration.
- 2 Consult the installation instructions to plan all aspects of the fixture installation.
- 3 Power consumption is typically 20% higher for 12 in fixture lengths.
- 4 Consult factory for products that are BAA-approved (Buy America.n Act).
- 5 8x8, 10x10, 10x30, 10x60, 10x90, 15x25 and WW distributions come with a half-frosted lens to bring light low on the wall for grazing applications. Clear lens also available, consult factory.
- 6 For best results, we recommend a 6 in setback from surface. Contact factory for application support.
- 7 Do not specify a tilt setting for the asymmetric wallwash option. The asymmetric wallwash optic is factory set with a 2.5 degree tilt.
- 8 Tilt setting is factory set and cannot be adjusted in the field.
- 9 The addition of an internal louver will affect beam distribution. Consult factory for application support.
- 10 A Lumentranslator 2 (LTL2) and LumentalkID (LIDLT) must be specified for Lumentalk applications. Consult Lumentranslator 2 and Lumentalk pages and specification sheets for details.
- 11 Available for DWW color temperature option only.
- 12 A control box (CBX) and LumenID (LID) must be specified.
- 13 DALI 2 T8 controller required, provided by others. DALI2 T8 control uses a single DALI short address.
- 14 Consult European specification sheet and installation instructions for CE wiring information.